| 4. Features
of the YS5G22D01
control board
water faucet
water box
Remark: The picture is for reference only.
5.Operating
Instructions

1、 ON/OFF:press to turn on and off
2、 Mode:press to run auto and manual mode to generate
water auto manual
3、Chilling: control chilled water mode,press to turn on
and off.
4、 Heating:control hot water mode,press to turn on and
off.
5、Fan : control the fan speed. A high speed will produce
more water.a lower speed will be quieter.
highspeed lower speed
6 Cold:cold water will flow out from water faucet when
pressing the button all along, water will stop flowing out
when stop press the button
7 Hot water: hot water will flow out from water faucet
when pressing the button all along, water will stop flowing
out when stop press the button
6.
Maintenance:
1. Keep unit clean. Wipe the outer casing with a soft
damp cloth. Do not use any cleaning detergents.
2. Clean storage tank once in 2 months.
3. Change all 3 Activated Carbon Filters every 12 months
4. Clean Static Air Filter once a month to ensure proper
airflow.
5. Empty drip tray weekly.
Cleaning of Storage Tank:
The storage tank should be emptied if not used for an
extended period. Regular cleaning of tank is also recommended.
Procedure:
1. Turn the machine OFF.
2. Unscrew the Screw Cap at the back of the machine.
3. Empty the water into another container and dispose
the water.
4. Do not use any rough material (scourers etc.) to clean
tank.
5. Screw the Screw Cap back.
Cleaning of Static Air Filter:
Procedure:
1. Remove Static Air Filter.
2. Rinse with cold water under the tap.
3. Wipe dry
4. Install Static Air Filter back into its original position.
Filter Change:
Procedure:
1. Switch machine OFF and UNPLUG from wall outlet.
2. Remove the 2 screws from the rear panel.
3. Remove the panel
4. Remove fittings on filters
5. Remove filters by pulling slowly or pushing to the
side.
6. Wrap on the screw threads.
7. Tighten fittings
8. Check all connections for leaks
9. Replace panel
Replacement of Ultra Violet Light:
The Ultra Violet Light should be changed once a year
or when the alarm is activated.
Procedure:
1. Switch machine OFF and UNPLUG from wall outlet
2. Remove the 2 screws from the rear panel.
3. Remove the panel.
4. Unplug and remove the Ultra Violet Light located at
the top of the unit.
5. Remove the Ultra Violet Light slowly from the protective
plastic tube.
6. Replace with new Ultra Violet Light.
7. Replace panel.
|