| 7.
Technology Specifications
| Model |
YS5G22D01 |
Power supply |
200-240V/50Hz or 110-120V/60Hz |
Dehumidifier power |
620W
|
Cooling power |
100W
|
Water generating capacity |
20 Liters per day |
Ultra Violet Light:
|
4Wx2
|
| Filtration
|
3 Layers of Activated
Carbon Filters
|
1 Layer of P/P Soft
Filter
|
Main Water Tank Volume: |
8 litres
|
Chilled Water Tank
Volume |
3 litres
|
Chilled Water Temperature: |
4C ~10C
|
Refrigerant |
R134a
|
Working Temperature |
18C~ 45C
|
Working Humidity |
40% - 95%RH
|
Display |
LED |
Type of Package Carton |
(480 x 388 x 1315cm)
|
Weight Gross: 55kgs
Nett: |
52kgs |
8.Trouble-shooter
Problem |
Possible
causes |
What to do
|
| The unit do not run
|
The unit is unpluged |
Make sure the unit plug is pushed
completely into oulet
|
Power the surge |
Unplug the unit,after 3 mintes
plug unit back in and turn on
|
The fuse is blown
or circuit breaker is tripped |
Check the building fuse/circuit
box and replace fuse or reset breaker
|
The tank is full |
Normal operation
|
The humidity is under
45%RH |
Normal operation,pls run the
manual mode
|
| The unit is producing
less water
|
The humidity is under
45%RH |
Normal operation,pls run the
manual mode
|
Do not allow enough
time to remove the moisture |
|
Airflow is restricted |
Make sure there are no curtains
blinds,or furniture blocking the front or back of
unit. See the choosing a location’section of this
manual.
|
The ambient temperature
is under 18C |
Normal operation
d |
Water is not enough
cold |
Do not allow enough
time to run chilled water mode |
Normal operation
|
Water is not enough
hot |
Do not allow enough
time to run hot water mode |
Normal operation
|
Fan noise |
High fan speed |
Normal operation
|
Flash once Per 5 sec |
The water ultra-violet
light is broken. |
The water ultra-violet light
should be replaced
|
Flash twice Per 5
sec |
The cycle unltra-violet
light is broken. |
The cycle unltra-violet light
should be replaced.
|
Flash once per1 sec
|
Compressor cooling
|
Normal operation.The unit will
resume normal operation after 20 minutes
|
Flash once per2 sec |
The water pump needs
service |
The unit be service |
9.Frequently
asked questions
1. what is the ideal temperature and humidity to operate
machine?
The unit operates most efficiently at temperatures above
75F(24C) and humidity above 60%.
2. at what temperature and humidity will the unit not
operate?
If set on automatic the unit will not operate below approximately
45%humidity. The unit will operate at temperature below
65F(18C).
3. can the unit be operate below 45%humidity?
Yes, if manual operation is selected the unit can be operated
at less than 45%humidity but will make very little water
below 30% humidity.
4. at what humidity level will the unit not make water?
It will make little or no water below approximately 30%humidity.
5. how often should the filters be replaced?
Filter replaced intervals are dependant on severity and
amount of use .under normal operating conditions the filters
should be replaced yearly.
6. how often should the unit light be replaced?
The UV light usually will last more than one year .but
,for safety purposes it is recommended the light be replaced
yearly at the same time the filters are replaced.
7. why are there two fan speeds?
The high fan speed provides for increased air movement.with
more air movement more water is produced. At a higher fan
speed the noise level is higher.
8. what do I do if the unit produces more water than needed?
The excess water can be drained or collected from the
front spigots or rear drain and kept in a separate container
for later use.
9. how pure is the water?
The water is the purest nature can provide. It does not
come from the ground or the ocean where it can pick up contaminants.it
comes from the air we breath and is then filtered.
Therefore,it is not subjected to the normal cantaminants
and also there is no chemicals added such as chlorine.
|